Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.671
Filter
1.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 70(2): e20230700, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1535096

ABSTRACT

SUMMARY OBJECTIVE: This study aimed to evaluate cardiac contractility in fetuses from pregestational diabetes mellitus pregnancies by three-dimensional ultrasound using spatiotemporal image correlation in rendering mode. METHODS: A retrospective cross-sectional study was performed on 40 fetuses from nondiabetic pregnancies and 28 pregestational diabetic pregnancies between 20 and 33 weeks and 6 days. Cardiac contractility was assessed by measuring the ventricular myocardial area in diastole subtracted from the ventricular myocardial area in systole. RESULTS: Pregestational diabetic pregnancies had a lower maternal age than nondiabetic pregnancies (26.7 vs. 39.9 years, p=0.019). Cardiac contractility in fetuses from diabetic and nondiabetic pregnancies was similar (p=0.293). A moderately positive and significant correlation was observed between gestational age and cardiac contractility (r=0.46, p=0.0004). A 1-week increase in gestational age was responsible for a 0.1386 cm2 increase in cardiac contractility. CONCLUSION: Cardiac contractility as evaluated by three-dimensional ultrasound using spatiotemporal image correlation in rendering mode showed no significant differences across fetuses with and without pregestational diabetes.

2.
Dental press j. orthod. (Impr.) ; 29(1): e2423217, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550226

ABSTRACT

ABSTRACT Objective: This study evaluated the accuracy and precision of digital models acquisition using a home-built, low-cost scanning system based on the structured light method. Methods: a plaster model (PM) was scanned using the experimental device (SL) and a dental desktop scanner (DS). The teeth dimensions of PM and SL models were measured in triplicate, with a caliper and digitally, respectively. The agreement of the measurements of each model was evaluated using the intraclass correlation coefficient, and the validity between the different measurement techniques was assessed using the Bland-Altman analysis. The accuracy and precision of the models were qualitatively investigated using the mesh superposition of the SL and DS models. Results: A high intraclass correlation coefficient was observed in all models (PM=0.964; SL1=0.998; SL2=0.995; SL3=0.998), and there was no statistical difference between the measurements of the SL models (p>0.05). PM and SL model measurements were found to be in good agreement, with only 3.57% of the observed differences between the same measurement being located outside 95% limits of agreement according to Bland and Altman (0.43 and -0.40 mm). In the superimpositions of SL-SL and SL-DS models, areas of discrepancy greater than 0.5 mm were observed mainly in interproximal, occlusal, and cervical sites. Conclusion: These results indicate that the home-built SL scanning system did not possess sufficient accuracy and precision for many clinical applications. However, the consistency in preserving the dental proportions suggests that the equipment can be used for planning, storage, and simple clinical purposes.


RESUMO Objetivo: Este estudo avaliou a acurácia e a precisão da aquisição de modelos digitais utilizando um sistema de digitalização caseiro e de baixo custo baseado no método de luz estruturada. Material e Métodos: Para isso, um modelo de gesso (MG) foi digitalizado utilizando o dispositivo experimental (LE) e um scanner dental de mesa (SD). As dimensões dos dentes dos modelos MG e LE foram medidas em triplicata com um paquímetro e digitalmente, respectivamente. A concordância das medidas de cada modelo foi avaliada usando o coeficiente de correlação intraclasse, e a validade entre as diferentes técnicas de medição foi avaliada usando a análise de Bland-Altman. A acurácia e a precisão dos modelos foram investigadas qualitativamente usando a sobreposição de malhas dos modelos LE e SD. Resultados: Um alto coeficiente de correlação intraclasse foi observado em todos os modelos (MG=0,964; LE1=0,998; LE2=0,995; LE3=0,998) e não houve diferença estatística entre as medições dos modelos LE (p>0,05). As medições dos modelos MG e LE mostraram boa concordância, com apenas 3,57% das diferenças observadas entre as mesmas medições localizadas fora dos limites de concordância de 95% de acordo com a análise de Bland-Altman (0,43 e -0,40 mm). Nas sobreposições dos modelos LE-LE e LE-SD, foram observadas áreas de discrepância maiores que 0,5 mm principalmente nos sítios interproximais, oclusais e cervicais. Conclusões: Esses resultados indicam que o sistema de digitalização por luz estruturada caseiro não possui precisão e acurácia suficientes para muitas aplicações clínicas. No entanto, a consistência na preservação das proporções dentárias sugere que o equipamento pode ser usado para planejamento, armazenamento e propósitos clínicos simples.

3.
Article in English | LILACS-Express | LILACS | ID: biblio-1550993

ABSTRACT

Introduction: Three-dimensional printing is one of the technologies that promote change at an economic and social level, and one of the fundamental elements of industry 4.0. It has enormous potential for the future of medicine, establishing itself as a new paradigm. Despite its advantages, its use in our environment is incipient. Objective: To design and develop solutions based on three-dimensional technologies for the teaching and practice of biomedical sciences. Materials and methods: A technological development investigation was carried out between the Center for Assisted and Sustainable Manufacturing of the University of Matanzas and Matanzas University of Medical Sciences, between September 2019 and July 2022. The designs and fabrications were made from the acquisition of computed tomography images, or from a surface scanner, which were then processed, converted into Standard Tessellation Language format, printed, and post-processed. Virtual designs were developed using computer-aided design software. Results: Various solutions were developed including prototypes: biomodels for craniosynostosis repair and anatomical figures, custom cranial prosthesis mold, hand prosthesis, O2 line splitters, tissue scaffolds, syringe gun, face shields, breast prosthesis; autologous restoration mold and tissue expander. Conclusions: In all areas of application of this technology in medicine―except the printing of medicines, in the current context―, it is feasible to obtain solutions in the territory of Matanzas. It is therefore imperative that managers and the medical community in general, begin to acquire awareness, knowledge, and experience to ensure the optimal use of this technology.


Introducción: La impresión tridimensional es una de las tecnologías que promueve el cambio a nivel económico y social, y uno de los elementos fundamentales de la industria 4.0. Asimismo, constituye un enorme potencial para el futuro de la medicina, estableciéndose como un nuevo paradigma. A pesar de sus ventajas, su explotación en nuestro medio es incipiente. Objetivos: Diseñar y desarrollar soluciones basadas en tecnologías tridimensionales para la enseñanza y la práctica de las ciencias biomédicas. Materiales y métodos: Se realizó una investigación colaborativa, de desarrollo tecnológico entre el Centro de Fabricación Asistida y Sostenible de la Universidad de Matanzas y la Universidad de Ciencias Médicas de Matanzas, entre septiembre de 2019 y julio de 2022. Los diseños y fabricaciones se realizaron a partir de la adquisición de imágenes de tomografía computarizada, o desde un escáner de superficie, las que luego se procesaron, se convirtieron en formato Standard Tessellation Language, se imprimieron y posprocesaron. Los diseños virtuales se desarrollaron empleando un software de diseño asistido por computadora. Resultados: Se desarrollaron varias soluciones que incluyen varios prototipos: biomodelos para reparación de craneosinostosis y figuras anatómicas, molde de prótesis craneal personalizada, prótesis de mano, divisores de líneas de O2, andamios tisulares, pistola portajeringas, protectores faciales, prótesis de mama, molde para restauración autóloga y expansor tisular. Conclusiones: En todas las áreas de aplicación de esta tecnología en medicina―salvo en la impresión de medicamentos, en el contexto actual―, es factible obtener soluciones en el territorio de Matanzas. Es un imperativo, pues, que directivos y la comunidad médica en general, comiencen a adquirir conciencia, conocimientos y experiencias para garantizar la utilización óptima de esta tecnología.

4.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 59-64, 2024.
Article in Chinese | WPRIM | ID: wpr-1006511

ABSTRACT

@#Objective    To investigate the clinical effect of 3D computed tomography bronchial bronchography and angiography (3D-CTBA) and guidance of thoracoscopic anatomic pulmonary segmentectomy by Mimics software system. Methods    A retrospective analysis was performed on patients who underwent thoracoscopic segmentectomy in the Department of Thoracic Surgery of Affiliated People's Hospital of Jiangsu University from June 2020 to December 2022. The patients who underwent preoperative 3D-CTBA using Materiaise's interactive medical image control system (Mimics) were selected as an observation group, and the patients who did not receive 3D-CTBA were selected as a control group. The relevant clinical indicators were compared between the two groups. Results    A total of 59 patients were included, including 29 males and 30 females, aged 25-79 years. There were 37 patients in the observation group, and 22 patients in the control group. The operation time (163.0±48.7 min vs. 188.8±43.0 min, P=0.044), intraoperative blood loss [10.0 (10.0, 20.0) mL vs. 20.0 (20.0, 35.0) mL, P<0.001], and preoperative puncture localization rate (5.4% vs. 31.8%, P=0.019) in the observation group were better than those in the control group. There was no statistically significant difference in the thoracic tube placement time, thoracic fluid drainage volume, number of intraoperative closure nail bin, postoperative hospital stay, or postoperative air leakage incidence (P>0.05) between the two groups. Conclusion    For patients who need to undergo anatomical pulmonary segmentectomy, using Mimics software to produce 3D-CTBA before surgery can help accurately identify pulmonary arteriovenous anatomy, reduce surgical time and intraoperative blood loss, help to determine the location of nodules and reduce invasive localization before surgery, and alleviate patients' pain, which is worthy of clinical promotion.

5.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 169-177, 2024.
Article in Chinese | WPRIM | ID: wpr-1006509

ABSTRACT

Objective@#To investigate the effects of electrochemically dealloying of Ti6Al4V abutments on human gingival fibroblasts (HGFs) and to provide experimental evidence for surface modification of implant abutments.@*Methods@#The samples were divided into an NC group (negative control, no other treatment on a smooth surface), an NM-1 group (nanomesh-1, electrochemical dealloying treatment in 1 mol/L NaOH 1 h on 2 V voltage), and an NM-2 group (nanomesh-2, electrochemical dealloying treatment in 5 mol/L NaOH 1 h on 2 V voltage). The surface morphologies of the samples and the adhesion of HGFs on the sample surfaces were observed with scanning electron microscopy (SEM). The surface hydrophilicities of the samples were measured with a contact angle measuring instrument. The proliferation of HGFs on the different samples were evaluated with CCK-8, and the expression of adhesion-related genes, including collagen Ⅰ (COL1A1), collagen Ⅲ (COL3A1), fibronectin 1 (FN1), focal adhesion kinase (FAK), vinculin (VCL), integrin α2 (ITGA2), and integrin β1 (ITGB1), on the different samples was measured with qRT-PCR. The expression of vinculin on the surfaces of HGFs was observed via confocal laser scanning microscopy (CLSM) after immunofluorescent staining. Collagen fiber secretion and syntheses of HGFs from different samples were evaluated via Sirius red staining.@*Results@#SEM revealed the formation of ordered and uniform three-dimensional mesh structures on the surfaces of the NM-1 and NM-2 groups, with grid diameters of approximately 30 nm for the NM-1 group and approximately 150 nm for the NM-2 group. Compared with that of the NC group, the water contact angles of the NM-1 group and NM-2 groups were significantly lower (P<0.000 1). Cell proliferation in the NM-1 group was significantly greater than that in the NC group (P<0.01). Moreover, there was no significant difference in the water contact angles or cell proliferation between the NM-1 group and the NM-2 group. SEM revealed that HGFs were adhered well to the surfaces of all samples, while the HGFs in the NM-1 and NM-2 groups showed more extended areas, longer morphologies, and more developed pseudopodia than did those in the NC group after 24 h. qRT-PCR revealed that the expression levels of the adhesion-related genes COL1A1, COL3A1, FN1, FAK and VCL in the NM-1 group were significantly greater than those in the NC and NM-2 groups (P<0.01). The expression of vinculin protein in the NM-1 group was the highest, and the number of focal adhesions was greatest in the NM-1 group (P<0.01). The results of Sirius red staining showed that the NM-1 group had the highest secretion and syntheses of collagen fibers (P<0.000 1).@*Conclusion@#The three-dimensional nanomechanical structure of Ti6Al4V modified by electrochemical dealloying promoted the adhesion, proliferation, collagen fiber secretion and syntheses of HGFs, and electrochemical dealloying of Ti6Al4V with a grid diameter of approximately 30 nm obviously promoted HGF formation.

6.
Organ Transplantation ; (6): 82-89, 2024.
Article in Chinese | WPRIM | ID: wpr-1005237

ABSTRACT

Objective To analyze three-dimensional imaging characteristics and advantages for severe portal vein stenosis after liver transplantation, and to evaluate clinical efficacy of portal vein stent implantation. Methods Clinical data of 10 patients who received portal vein stent implantation for severe portal vein stenosis after liver transplantation were retrospectively analyzed. Imaging characteristics of severe portal vein stenosis, and advantages of three-dimensional reconstruction imaging and interventional treatment efficacy for severe portal vein stenosis were analyzed. Results Among 10 patients, 3 cases were diagnosed with centripetal stenosis, tortuosity angulation-induced stenosis in 2 cases, compression-induced stenosis in 2 cases, long-segment stenosis and/or vascular occlusion in 3 cases. Three-dimensional reconstruction images possessed advantages in accurate identification of stenosis, identification of stenosis types and measurement of stenosis length. All patients were successfully implanted with portal vein stents. After stent implantation, the diameter of the minimum diameter of portal vein was increased [(6.2±0.9) mm vs. (2.6±1.7) mm, P<0.05], the flow velocity at anastomotic site was decreased [(57±19) cm/s vs. (128±27) cm/s, P<0.05], and the flow velocity at the portal vein adjacent to the liver was increased [(41±6) cm/s vs. (18±6) cm/s, P<0.05]. One patient suffered from intrahepatic hematoma caused by interventional puncture, which was mitigated after conservative observation and treatment. The remaining patients did not experience relevant complications. Conclusions Three-dimensional visualization technique may visually display the location, characteristics and severity of stenosis, which is beneficial for clinicians to make treatment decisions and assist interventional procedures. Timely implantation of portal vein stent may effectively reverse pathological process and improve portal vein blood flow.

7.
International Eye Science ; (12): 62-66, 2024.
Article in Chinese | WPRIM | ID: wpr-1003507

ABSTRACT

The finite element method(FEM)is a widely employed mathematical technique in mechanical research that divides an object into discrete and interacting finite elements. Medically, finite element analysis(FEA)enables the simulation of biomechanical experiments that are challenging to conduct. Orbital surgery poses significant challenges to ophthalmologists due to its inherent difficulty and steep learning curve. FEM enables the simulation and analysis of the mechanical properties of orbital tissue, offering a novel approach for diagnosing and treating orbital-related diseases. With technological advancements, FEM has significantly matured in the diagnosis and treatment of orbital diseases, becoming a popular area of research in orbital biomechanics. This paper reviewed the latest advancements in orbital FEM, encompassing the development of orbital FEA models, simulation of orbital structure, and its application in orbital-related diseases. Additionally, the limitations of FEM and future research directions are also discussed. As a digital tool for auxiliary diagnosis and treatment, orbital FEA will progressively unlock its potential for diagnosing and treating orbital diseases alongside technological advancements.

8.
Humanidad. med ; 23(3)dic. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1534560

ABSTRACT

Las enfermedades raras son aquellas que tienen baja prevalencia y que, por lo tanto, el desarrollo de medicamentos para tratarlas no es rentable para las empresas farmacéuticas debido a la baja demanda. A pesar de que ya se cuenta con diferentes políticas públicas alrededor del mundo para incentivar a las industrias farmacéuticas a investigar estos medicamentos, conocidos como medicamentos huérfanos, su desarrollo conlleva muchas dificultades en las evaluaciones clínicas y el precio final para el público es muy elevado. Si bien en años recientes se ha planteado el uso de tecnología de impresión en 3D para producir estos medicamentos o incluso recurrir a otros medicamentos previamente aprobados para tratar enfermedades raras, existe un historial de mal uso de las legislaciones por parte de las empresas con el fin de generar beneficios comerciales, por lo que estas políticas deben reforzarse para que cumplan su propósito; ayudar a una población muy vulnerable. El objetivo del presente texto es exponer los resultados de una revisión documental sobre el panorama científico y sociopolítico en el que se encuentra el problema de las enfermedades raras y los medicamentos huérfanos, así como las posibles soluciones que se están desplegando para abordarlo. Deriva de un estudio que se desarrolla en el momento actual en la Universidad Autónoma Metropolitana, de Ciudad de México.


The strange illnesses are those that have low prevalence and that, therefore, the development of medications to treat them is not profitable for the pharmaceutical companies due to the drop demands. Although it is already counted with different political public around the world to motivate to the pharmaceutical industries to investigate these medications, well-known as orphan medications, their development bears many difficulties in the clinical evaluations and the final price for the public it is very high. Although in recent years he/she has thought about the use of impression technology in 3D to produce these medications or even to appeal to other medications previously approved to treat strange illnesses, a record of wrong use of the legislations exists on the part of the companies with the purpose of generating commercial benefits, for what these politicians should be reinforced so that they complete its purpose; to help a very vulnerable population. The objective of the present text is to expose the results of a documental revision on the scientific and sociopolitical panorama in which is the problem of the strange illnesses and the orphan medications, as well as the possible solutions that they are spreading to approach it. It derives of a study that is developed in the current moment in the Metropolitan Autonomous University, of Mexico City.

9.
Braz. j. otorhinolaryngol. (Impr.) ; 89(5): 101289, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520503

ABSTRACT

Abstract Objectives: To present and execute a protocol for the capture of 3D facial images using photogrammetry through the open access software Blender and its add-on OrtogOnBlender (OOB) and to evaluate the compatibility of the 3D meshes generated with Computed tomography (CT) of the sinuses. Methods: Individuals > 18 years old, candidates for Rhinoseptoplasty in a tertiary hospital, were submitted to a photographic session to perform the standardized protocol. In the session, divided into 3 phases, sequential photos were taken for processing the photogrammetry in the OOB and producing 3D meshes of the face. The photogrammetry reconstructions were compared with the reference mesh of the soft tissue surface of the Sinus CT scan to assess compatibility between them. Results: 21 patients were included, 67% female. 3 photogrammetry meshes and 1 CT reference mesh were generated, which demonstrated matching compatibility, as most of the mean distances between cloud points were <1.48mm. Phase 3 of the session with the highest number of photos (54.36 ± 15.05) generated the most satisfactory mesh with the best resolution. Conclusions: The proposed protocol is reproducible and feasible in clinical practice, generated satisfactory 3D meshes of the face, being a potential tool for surgical planning and comparison of results. For the implementation of photogrammetry for use in 3D anthropometry, it is necessary to validate this method. Level of evidence: 3. OCEBM Levels of Evidence Working Group.1 The Oxford 2011 Levels of Evidence. Oxford Centre for Evidence-Based Medicine. http://www.cebm.net/index.aspx?o=5653

10.
Rev. bras. ortop ; 58(4): 604-610, July-Aug. 2023. graf
Article in English | LILACS | ID: biblio-1521797

ABSTRACT

Abstract Objective The interest in using 3D printing in the healthcare field has grown over the years, given its advantages and potential in the rapid manufacturing of personalized devices and implants with complex geometries. Thus, the aim of the present study was to compare the mechanical fixation behavior of a 3D-printed interference screw, produced by fused deposition modeling of polylactic acid (PLA) filament, with that of a titanium interference screw. Methods Eight deep flexor porcine tendons, approximately 8 mm wide and 9 cm long, were used as graft and fixed to a 40 pounds-per-cubic-foot (PCF) polyurethane block at each of its extremities. One group was fixed only with titanium interference screws (group 1) and the other only with 3D-printed PLA screws (BR 20 2021 018283-6 U2) (group 2). The tests were conducted using an EMIC DL 10000 electromechanical universal testing machine in axial traction mode. Results Group 1 (titanium) obtained peak force of 200 ± 7 N, with mean graft deformation of 8 ± 2 mm, and group 2 (PLA) obtained peak force of 300 ± 30 N, and mean graft deformation of 7 ± 3 mm. Both the titanium and PLA screws provided good graft fixation in the polyurethane block, with no slippage or apparent deformation. In all the samples, the test culminated in graft rupture, with around 20 mm of deformation in relation to the initial length. Conclusion The 3D-printed PLA screw provided good fixation, similar to that of its titanium counterpart, producing satisfactory and promising results.


Resumo Objetivo O interesse em utilizar a impressão 3D na área da saúde tem crescido ao longo dos anos, dadas as suas vantagens e o seu potencial na rápida fabricação de dispositivos e implantes personalizados com geometrias complexas. Assim, o objetivo do presente estudo foi comparar o comportamento de fixação mecânica de um parafuso de interferência impresso em 3D, produzido pela modelagem fundida de deposição do filamento de ácido polilático (PLA), com o de um parafuso de interferência de titânio. Métodos Oito tendões suínos flexores profundos, de aproximadamente 8 mm de largura e 9 cm de comprimento, foram utilizados como enxerto e fixados em um bloco de poliuretano de 40 PCF em cada uma de suas extremidades. Um grupo foi fixado apenas com parafusos de interferência de titânio (grupo 1) e o outro apenas com parafusos PLA impressos em 3D (BR 20 2021 018283-6 U2) (grupo 2). Os testes foram realizados utilizando uma máquina de teste universal eletromecânica EMIC DL 10.000 no modo de tração axial. Resultados O grupo 1 (titânio) obteve força máxima de 200 ± 7 N com deformação média do enxerto de 8 ± 2 mm, e a força máxima do grupo 2 (PLA) foi de 300 ± 30 N e deformação média do enxerto de 7 ± 3 mm. Ambos os parafusos de titânio e PLA forneceram boa fixação de enxerto no bloco de poliuretano, sem deslizamento ou deformação aparente. Em todas as amostras o teste culminou na ruptura do enxerto, com cerca de 20 mm de deformação em relação ao comprimento inicial. Conclusão O parafuso PLA impresso em 3D proporcionou boa fixação, semelhante à de sua contraparte de titânio, produzindo resultados satisfatórios e promissores.


Subject(s)
Animals , Swine , Tendons/surgery , Bone Screws , Lactic Acid , Printing, Three-Dimensional
11.
Rev. bras. ginecol. obstet ; 45(7): 409-414, July 2023. tab, graf
Article in English | LILACS | ID: biblio-1507871

ABSTRACT

Abstract In this integrative review, we aimed to describe the records of time devoted by physicians to breast ultrasound in a review of articles in the literature, in order to observe whether the automation of the method enabled a reduction in these values. We selected articles from the Latin American and Caribbean Literature in Health Sciences (LILACS) and MEDLINE databases, through Virtual Health Library (BVS), SciELO (Scientific Electronic Library Online), PubMed, and Scopus. We obtained 561 articles, and, after excluding duplicates and screening procedures, 9 were selected, whose main information related to the guiding question of the research was synthesized and analyzed. It was concluded that the automation of breast ultrasound represents a possible strategy for optimization of the medical time dedicated to the method, but this needs to be better evaluated in comparative studies between both methods (traditional and automated), with methodology directed to the specific investigation of this potentiality.


Resumo Na presente revisão integrativa, objetivamos descrever os registros de tempo dedicado pelos médicos à ultrassonografia mamária em revisão de artigos da literatura, visando observar se a automação do método possibilitou redução destes valores. Selecionamos artigos nas bases de dados Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS) e MEDLINE, através da Biblioteca Virtual em Saúde (BVS), Scientific Electronic Library Online (SciELO), PubMed e Scopus. Obtivemos 561 artigos e, após a exclusão de artigos duplicados e procedimentos de triagem, foram selecionados 9 artigos, cujas informações principais relativas à pergunta norteadora da pesquisa foram sintetizadas e analisadas. Foi concluído que a automação da ultrassonografia mamária representa uma possível estratégia de otimização do tempo médico dedicado ao método; porém, essa conclusão necessita ser melhor avaliada em estudos comparativos entre ambos os métodos (tradicional e automatizado), com metodologia direcionada à investigação específica desta potencialidade.


Subject(s)
Humans , Female , Breast Neoplasms/diagnostic imaging , Ultrasonography, Mammary , Imaging, Three-Dimensional
12.
Indian Heart J ; 2023 Jun; 75(3): 177-184
Article | IMSEAR | ID: sea-220979

ABSTRACT

Objective: We sought to evaluate the myocardial strain by four-dimensional speckle-tracking echocardiography (4D-STE) in patients with stable angina pectoris (SAP) to determine the severity of coronary artery disease (CAD) based on the Gensini score. Methods: The present study comprised of 150 patients with SAP. Patients with history of SAP, normal left ventricular ejection fraction, and without regional wall motion abnormalities (RWMA) were scheduled for elective coronary angiography. Based on Gensini score, there were two groups: non-critical stenosis group [Gensini score (0e19), n ¼ 117] and critical stenosis group [Gensini score 20, n ¼ 33]. Correlation between Gensini score and 4D-STE strain parameters were investigated. Results: Out of 150 patients, critical stenosis group had significantly depressed values of all 4D-STE strain parameters than non-critical stenosis group (p < 0.001), except global radial strain (GRS) parameter. Significant positive correlation was found between Gensini score and 4D global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) with Spearman's correlation coefficient (r) as 0.626, 0.548, and 0.631, respectively (p < 0.001), whereas significant negative correlation was found between Gensini score and GRS (r ¼ 0.433, p < 0.001). A 4D GLS value of 17 had 84.9% sensitivity and 97.4% specificity, GAS 31 (90.9% sensitivity, 78.6% specificity), GCS 17 (69.7% sensitivity, 92.3% specificity), and GRS <47 (sensitivity 72.7%, specificity 76.1%) to detect critical CAD described by Gensini score 20. Conclusion: The 4D-STE can aid in the assessment of severe CAD stenosis with good sensitivity and specificity in the patients with SAP without RWMA on traditional echocardiography.

13.
Article | IMSEAR | ID: sea-219304

ABSTRACT

Transcatheter mitral valve replacement (TMVR) has emerged as a feasible alternative to surgical reoperation in failed bioprostheses and rings. Residual mitral regurgitation following TMVR can present as a valve?in?valve paravalvular leak (PVL) and is associated with increased morbidity and mortality. Current therapies for valve?in?valve PVL are limited. We present a case of a symptomatic patient with severe valve?in?valve PVL after TMVR for a previous surgical bioprosthesis leak, who then underwent a second TMVR as a valve?in?valve?in?valve implantation with a 29 mm Edwards? SAPIEN 3 valve via transseptal approach using three?dimensional (3D) echocardiography. This unique case highlights the complexity of this clinical entity and recognizes 3D transesophageal echocardiography as a valuable tool to guide valve?in?valve PVL closures.echocardiography

14.
Int. j. morphol ; 41(3): 873-880, jun. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1514311

ABSTRACT

SUMMARY: Due to the complexity of head shape, limited 1D or 2D head anthropometry fail to fully capture its shape characteristics. Currently, there is limited research on clustering analysis of head shape from a shape difference perspective, especially for the head shape of Chinese people. Head shape is influenced by factors such as race, sex, and age, making it imperative to create a head shape database for Chinese individuals. In this study, three-dimensional head data of 339 Chinese young adult were collected, and the head shapes were clustered into 7 clusters using an improved k-medoids algorithm. The differences between clusters and the average head shape were further analyzed. It can be foreseen that the head shape database for Chinese young adult constructed in this study has important reference value for the ergonomic design of head-related products and head morphology research, among other fields.


Debido a la complejidad de la forma de la cabeza, la antropometría limitada de ésta, en 1D o 2D, no logra capturar completamente sus características de forma. Actualmente, existen estudios limitados sobre el análisis de agrupamiento de la forma de la cabeza, desde una perspectiva de diferencia de forma, especialmente en el caso de la población china. La forma de la cabeza está influenciada por factores como la raza, el sexo y la edad, por lo que resulta imperativo crear una base de datos sobre la forma de la cabeza de los individuos chinos. En este estudio, se recopilaron datos tridimensionales de la cabeza de 339 adultos jóvenes chinos, y las formas de la cabeza se agruparon en 7 grupos utilizando un algoritmo k-medoids mejorado. Las diferencias entre los grupos y la forma promedio de la cabeza se analizaron a profundidad. Se puede prever que la base de datos sobre la forma de la cabeza de adultos jóvenes chinos construida en este estudio, tiene un valor de referencia importante para el diseño ergonómico de productos relacionados con la morfología de la cabeza, entre otros campos.


Subject(s)
Humans , Adolescent , Adult , Young Adult , Anthropometry , Imaging, Three-Dimensional , Head/anatomy & histology
15.
Article | IMSEAR | ID: sea-218851

ABSTRACT

Rapid maxillary expansion is often considered the treatment of choice for the correction of maxillary constriction. Several studies highlight the effect of rapid maxillary expansion in increasing nasal length and volume. The aim of this study is quantifying the volumetric changes of the upper airway, the maximum restricted area of the upper airway and the nostrils area, after the intervention of a rapid maxillary expansion using bimaxillary CBCT. A retrospective study was carried out, in which 14 patients of 12 year old with a diagnosis of unilateral or bilateral crossbite and skeletal maxillary constriction were selected. The treatment was carried out with a Mcnamara-type rapid expansion device and 8 mm of disjunction was planned. An initial bimaxillary CBCT was requested and another 15 days after treatment. Measurements were made at the maxillary level, upper airway and the maximum restricted area and the cross section of the nostril area, using 3D measuring softwares. It was obtained that, for every 1 mm of planned disjunction, 0.65 mm of maxillary disjunction is achieved, an upper airway gain of 0.7 cm3, the maximum restricted area gain of the upper airway of 9 mm2 and a gain in the nostrils area of 7.4 mm2 on average. In conclusion rapid maxillary expansion generates a significant increase in the volume of the upper airway and its narrower area.

16.
Int. j. morphol ; 41(2): 410-416, abr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1440298

ABSTRACT

SUMMARY: The foramen magnum is an important topographic opening which connects cranial cavity and spinal canal. The analysis of the bone material established that there are differences in the shape of the foramen magnum between individuals. The aim of this study was to determine sex based on shape and size of foramen magnum using geometric morphometrics method. A study was performed on three-dimensional models (3D models) of 214 human skulls of known sex and known age (141 male skulls and 73 female skulls). The skulls are located at the museum of Medical Faculty, University of Sarajevo. Skulls belong to Bosnian population from the mid-twentieth century. All examined skulls were scanned with a laser scanner to obtain their 3D models. On 3D models of the examined skulls, four landmarks were marked on foramen magnum. Analysis of sex determination was performed using the MorphoJ program. Results of this study showed that there are sex differences in the shape and size of the foramen magnum. Sex determination based on the shape and size of the foramen magnum was showed 65.25 % accuracy for male and 63.01 % accuracy for female using geometric morphometrics method. Examination of the effect of size of foramen magnum on sexual dimorphism of shape of foramen magnum showed a statistically significant effect. Sex determination based just on the shape of foramen magnum using geometric morphometrics method was possible with 62.41 % accuracy for male and 58.90 % accuracy for female on examined sample. Sex differences on shape and size of foramen magnum were found using geometric morphometrics method on three-dimensional models of the examined skulls. The percentage of accuracy was higher for male based on the shape and size of the foramen magnum than for female.


El foramen magno es una importante abertura topográfica que conecta la cavidad craneal y el canal espinal. El análisis del material óseo estableció que existen diferencias en la forma del foramen magno entre individuos. El objetivo de este estudio fue determinar el sexo en función de la forma y el tamaño del foramen magno utilizando morfometría geométrica. El estudio se realizó en modelos tridimensionales (modelos 3D) de 214 cráneos humanos de sexo y edad conocidos (141 cráneos masculinos y 73 cráneos femeninos). Los cráneos se encuentran en el museo de la Facultad de Medicina de la Universidad de Sarajevo. Los cráneos pertenecen a población bosnia de mediados del siglo XX. Todos los cráneos examinados fueron escaneados con un escáner láser para obtener sus modelos 3D. En los modelos 3D de los cráneos examinados, se marcaron cuatro puntos de referencia en el foramen magno. El análisis de determinación de sexo se realizó utilizando el programa MorphoJ. Los resultados de este estudio mostraron que existen diferencias de sexo en la forma y el tamaño del foramen magno. La determinación del sexo basada en la forma y el tamaño del foramen magno mostró una precisión del 65,25 % para los hombres y del 63,01 % para las mujeres utilizando morfometría geométrica. El examen del efecto del tamaño del foramen magno sobre el dimorfismo sexual de la forma del foramen magno mostró un efecto estadísticamente significativo. La determinación del sexo basada solo en la forma del foramen magno utilizando morfometría geométrica fue posible con una precisión del 62,41 % para los hombres y del 58,90 % para las mujeres en la muestra examinada. Se encontraron diferencias de sexo en la forma y el tamaño del foramen magno utilizando morfometría geométrica en modelos tridimensionales de los cráneos examinados. El porcentaje de precisión fue mayor para los hombres en función de la forma y el tamaño del foramen magno que para las mujeres.


Subject(s)
Humans , Male , Female , Sex Determination by Skeleton , Printing, Three-Dimensional , Foramen Magnum/anatomy & histology , Regression Analysis , Principal Component Analysis
17.
Rev. bras. ortop ; 58(2): 284-289, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449810

ABSTRACT

Abstract Objective Due to the popularity of 3D technology, surgeons can create specific surgical guides and sterilize them in their institutions. The aim of the present study is to compare the efficacy of the autoclave and ethylene oxide (EO) sterilization methods for objects produced by 3D printing with polylactic acid (PLA) material. Methods Forty cubic-shaped objects were printed with PLA material. Twenty were solid and 20 were hollow (printed with little internal filling). Twenty objects (10 solid and 10 hollow) were sterilized in autoclave, forming Group 1. The others (10 solid and 10 hollow) were sterilized in EO, composing Group 2. After sterilization, they were stored and referred to culture. Hollow objects of both groups were broken during sowing, communicating the dead space with the culture medium. The results obtained were statistically analyzed (Fisher exact test and residue analysis). Results In group 1 (autoclave), there was bacterial growth in 50% of solid objects and in 30% of hollow objects. In group 2 (EO), growth occurred in 20% of hollow objects, with no bacterial growth in solid objects (100% of negative samples). The bacteria isolated in the positive cases was non-coagulase-producing Staphylococcus Gram positive. Conclusions Sterilization by both autoclave and EO was not effective for hollow printed objects. Solid objects sterilized by autoclave did not demonstrate 100% of negative samples and were not safe in the present assay. Complete absence of contamination occurred only with solid objects sterilized by EO, which is the combination recommended by the authors.


Resumo Objetivo Devido à popularidade da tecnologia 3D, cirurgiões podem criar guias cirúrgicos específicos e esterilizá-los nas suas instituições. O objetivo do presente estudo é comparar a eficácia dos métodos de esterilização por autoclave e óxido de etileno (OE) de objetos produzidos pela impressão 3D com material ácido polilático (PLA, na sigla em inglês). Métodos Quarenta objetos em formato cúbico foram impressos com material de PLA. Vinte eram sólidos e 20 eram ocos (impressos com pouco enchimento interno). Vinte objetos (10 sólidos e 10 ocos) foram esterilizados em autoclave, formando o Grupo 1. Os demais (10 sólidos e 10 ocos) foram esterilizados em OE, compondo o Grupo 2. Após a esterilização, os objetos foram armazenados e encaminhados para cultura. Objetos ocos de ambos os grupos foram quebrados durante a semeadura, comunicando o espaço morto com o meio de cultura. Os resultados obtidos foram analisados estatisticamente (teste exato de Fisher e análise de resíduo). Resultados No grupo 1 (autoclave) houve crescimento bacteriano em 50% dos objetos sólidos e em 30% dos objetos ocos. No grupo 2 (OE) o crescimento ocorreu em 20% dos objetos ocos, com ausência de crescimento bacteriano nos objetos sólidos (100% de amostras negativas). A bactéria isolada nos casos positivos foi Staphylococcus Gram positivo não produtor de coagulase. Conclusões A esterilização tanto em autoclave quanto pelo OE não foi eficaz para objetos impressos no formato oco. Objetos sólidos esterilizados em autoclave não demonstraram 100% de amostras negativas, não sendo seguro no presente ensaio. Ausência completa de contaminação ocorreu apenas com objetos sólidos esterilizados pelo OE, sendo a combinação recomendada pelos autores.


Subject(s)
Humans , Arthroplasty, Replacement, Hip/rehabilitation , Analgesia , Injections, Intra-Articular
18.
Rev. bras. ortop ; 58(2): 303-312, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449806

ABSTRACT

Abstract Objective To evaluate a proposed three-dimensional (3D) printing process of a biomodel developed with the aid of fused deposition modeling (FDM) technology based on computed tomography (CT) scans of an individual with nonunion of a coronal femoral condyle fracture (Hoffa's fracture). Materials and Methods Thus, we used CT scans, which enable the evaluation of the 3D volumetric reconstruction of the anatomical model, as well as of the architecture and bone geometry of sites with complex anatomy, such as the joints. In addition, it enables the development of the virtual surgical planning (VSP) in a computer-aided design (CAD) software. This technology makes it possible to print full-scale anatomical models that can be used in surgical simulations for training and in the choice of the best placement of the implant according to the VSP. In the radiographic evaluation of the osteosynthesis of the Hoffa's fracture nonunion, we assessed the position of the implant in the 3D-printed anatomical model and in the patient's knee. Results The 3D-printed anatomical model showed geometric and morphological characteristics similar to those of the actual bone. The position of the implants in relation to the nonunion line and anatomical landmarks showed great accuracy in the comparison of the patient's knee with the 3D-printed anatomical model. Conclusion The use of the virtual anatomical model and the 3D-printed anatomical model with the additive manufacturing (AM) technology proved to be effective and useful in planning and performing the surgical treatment of Hoffa's fracture nonunion. Thus, it showed great accuracy in the reproducibility of the virtual surgical planning and the 3D-printed anatomical model.


Resumo Objetivo Avaliar uma proposta de processo de impressão tridimensional (3D) de um biomodelo preparado com o auxílio da tecnologia de modelagem por deposição de material fundido (fused deposition modeling, FDM, em inglês) a partir de imagens de tomografia computadorizada (TC) de um indivíduo com pseudartrose de fratura coronal do côndilo femoral (fratura de Hoffa). Materiais e Métodos Para tanto, utilizamos imagens de TC, que permitem estudar a reconstrução volumétrica 3D do modelo anatômico, além da arquitetura e geometria óssea de sítios de anatomia complexa, como as articulações. Também permite o planejamento cirúrgico virtual (PCV) em um programa de desenho assistido por computador (computer-aided design, CAD, em inglês). Essa tecnologia possibilita a impressão de modelos anatômicos em escala real que podem ser utilizados em simulações cirúrgicas para o treinamento e a escolha do melhor posicionamento do implante de acordo com o PCV. Na avaliação radiográfica da osteossíntese da pseudartrose de Hoffa, verificou-se a posição do implante no modelo anatômico impresso em 3D e no joelho do paciente. Resultados O modelo anatômico impresso em 3D apresentou características geométricas e morfológicas semelhantes às do osso real. O posicionamento dos implantes em relação à linha de pseudartrose e pontos anatômicos foram bastante precisos na comparação do joelho do paciente com o modelo anatômico impresso em 3D. Conclusão A utilização do modelo anatômico virtual e do modelo anatômico impresso em 3D com a tecnologia de manufatura aditiva (MA) foi eficaz e auxiliou o planejamento e a realização do tratamento cirúrgico da pseudartrose da fratura de Hoffa. Desta forma, foi bastante preciso na reprodutibilidade do planejamento cirúrgico tanto virtual quanto no modelo anatômico impresso em 3D.


Subject(s)
Humans , Pseudarthrosis , Orthopedic Procedures , Printing, Three-Dimensional , Hoffa Fracture/surgery
19.
Article | IMSEAR | ID: sea-219283

ABSTRACT

Background:Transesophageal echocardiography (TEE) probe insertion may be associated with many complications. Demographic factors and airway conditions such as high Mallampati scores (MMC) and Cormack-Lehane grades (MCLG) are likely to have an impact on its ease of insertion. The primary aim of this study was to identify the predictive factors for difficult real-time-three-dimensional TEE probe insertion. Methods: A total of 153 adult patients undergoing cardiac surgery were prospectively evaluated. The upper airway manipulations required for TEE probe placement were jaw thrust, reverse Sellick抯 maneuver, and laryngoscopy. All the patients who required airway manipulations were grouped under difficult TEE probe placement group. We evaluated the patients� predictive factors such as demographic characteristics and factors related to difficult intubation. Results: Out of 153 patients, 123 were males and 30 were females. Overall, 27.5% (n = 42) patients had difficulty in probe placement. About 31.7% (n = 39) males had difficulty in TEE probe placement against 13% (n = 4) females (P?value 0.045). Difficulty in TEE probe placement was found in 72.7% (n = 16) of obese patients (body mass index [BMI] > 30), compared to 18.6% (n = 17) in the patients with BMI less than 25 (P-value < 0.001). Probe insertion was significantly more difficult in the presence of MMC III and IV (50%, n = 18) compared to class I (19.2%, n = 10) (P?value 0.001) and MCLG III (73.3%, n = 22) compared to grade I (11.1%, n = 7) (P-value 0.001). Conclusion: Male gender, obesity, higher grades of MMC and MCLG were found to be the risk factors for difficult TEE probe placement in anesthetized patients.

20.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1431959

ABSTRACT

La tecnología de fabricación aditiva o impresión 3D se ha posicionado como una herramienta transversal y de uso creciente en el mundo productivo y científico que ha otorgado la posibilidad de diseñar y crear elementos y modelos de diversa complejidad. En el área biomédica ha presentado un aumento significativo de sus aplicaciones a través del tiempo, actualmente teniendo relevancia en ámbitos como el planeamiento quirúrgico, la creación de prótesis, modelos anatómicos para educación y entrenamiento quirúrgico. Actualmente existen diversas dificultades que limitan la formación quirúrgica, especialmente en ciertas áreas de la otorrinolaringología como la cirugía de oído. El objetivo de la presente revisión narrativa fue actualizar los usos de la tecnología de impresión 3D para la creación de modelos para entrenamiento quirúrgico en otorrinolaringología, destacando sus potenciales usos en otología, rinología, cirugía de base de cráneo y vía aérea.


Additive manufacturing technology or 3D printing has positioned itself as a cross-cutting tool of increasing use in the productive and scientific world that has given the possibility of designing and creating different elements and models of varying complexity. In the biomedical area, it has presented a significant increase in its applications over time, currently having relevance in areas such as surgical planning, the creation of prostheses, anatomical models for education and surgical training. Currently there are various difficulties that limit surgical training, especially in certain areas of otorhinolaryngology such as ear surgery. The objective of this narrative review was to update the uses of 3D printing technology for the creation of models for surgical training in otorhinolaryngology, highlighting its potential uses in otology, rhinology, skull base and airway surgery.

SELECTION OF CITATIONS
SEARCH DETAIL